One of the more common failures of water bottle systems is the routing valve. Routing toggles are used in multiple places on the water bottle system: the purge, bottle selector and city/bottle selector. A failure of the purge can cause an air/water crossover condition while a failure of the city/bottle switch can cause a bottle to fill up, resulting in water getting into the on/off toggle and leaking out. Replace routing valve with 7001 (gray) or 7000 (black).